CDCBV - V48-727/V49-727 VITA OMEGA OPAQUE LIQUID SF

  • MSDS: CDCBV
  • Manufacturer: VIDENT
  • Product Name: V48-727/V49-727 VITA OMEGA OPAQUE LIQUID SF
  • National Stock Number: 6550-00F052760
Product Identification

Product ID:V48-727/V49-727 VITA OMEGA OPAQUE LIQUID SF
MSDS Date:04/15/1993
FSC:6550
NIIN:00F052760
MSDS Number: CDCBV

Responsible Party
VIDENT
5130 COMMERCE DR
BALDWIN PARK, CA 91706-5000
US

Emergency Phone: 818-960-7531

Info Phone: 818-960-7531

Cage: 67251

Contractor
VIDENT
BALDWIN PARK, CA 91706 US

Telephone: 818-962-4220

Cage: 67251

Ingredients

ACETIC ACID (GLACIAL), ETHANOIC ACID *98-2*

CAS: 64-19-7

RTECS: AF1225000

OSHA PEL 25 MG/CUM

ACGIH TLV: 25 MG/CUM

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


CELLULOSE

CAS: 9004-34-6

RTECS: FJ5691460

OSHA PEL 5 MG/CUM

ACGIH TLV: 10 MG/CUM (DUST)


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Hazards

Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:NONE
Explanation of Carcinogenicity:NONE
Effects of Overexposure:NONE

First Aid

First Aid:OBTAIN MEDICAL ATTENTION IN ALL CASES.

Fire Fighting

Flash Point:NON-FLAMMABLE
Fire Fighting Procedures:NONE
Unusual Fire/Explosion Hazard:NONE

Accidental Release

Spill Release Procedures:WIPE. LET ABSORB ON PAPER TOWEL.

Handling

Handling and Storage Precautions:NONE

Exposure Controls

Respiratory Protection:NOT REQUIRED
Ventilation:NOT REQUIRED
Protective Gloves:NOT REQUIRED
Eye Protection:NOT REQUIRED
Other Protective Equipment:NOT REQUIRED
Work Hygienic Practices:NOT REQUIRED
Supplemental Safety and Health

Chemical Properties

Boiling Pt:B.P. Text:212F
Spec Gravity:1
Solubility in Water:COMPLETE
Appearance and Odor:COLORLESS LIQUID W/NO ODOR

Stability

Stability Indicator/Materials to Avoid:YES
NONE
Hazardous Decomposition Products:NONE

Disposal

Waste Disposal Methods:SWEEP TO SEWER. DISPOSE OF IN ACCORDANCE
W/LOCAL, STATE & FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.